Source Technologies ST9620 Printer User Manual


 
Source Technologies, LLC ST9620 Secure MICR Printer User’s Guide
50
d..d Data to be printed
$ Command terminator
This command identifies the data to be printed in the sixth column of the report. This
field is a maximum of 19 characters.
Audit Report Field Seven &%SQ7d..d$
&SQ&7 Lead in string
d..d Data to be stored
$ Command terminator
This command identifies the data to be printed in the seventh column of the report. This
field is a maximum of 12 characters. The data in this field is recorded for the Audit
Report only.
Print and Purge Audit Report &%SPURGExx$
&%SPURGE Lead in string
x option(s)
$ Command terminator
This command prints and purges the Audit Report. All recorded information is deleted.
The optional field can be any combination of the following letters:
T Total Field 4
O Overlay
S Sort by MICR line
C Communicate - send report to host instead of printing - see additional
information below on SPRINT command
For example, the command &%SPURGES$ sorts the records by the MICR line while the
command &%SPURGESO$ sorts the records by the MICR line and prints an overlay
with the data.
Options can be forced on with these commands but they cannot be forced off. In other
words, if the front panel overlay setting is on, it cannot be forced off by a datastream
command. If the front panel overlay setting is off, however, a datastream command can
activate this feature. This command can only be accessed with a valid password
command.
Print Audit Report &%SPRINTxx$
&%SPRINT Lead in string
x option(s)
$ Command terminator
Prints the Audit Report
Audit Trail Reports | 8