Secure MICR Printer User’s Guide © Source Technologies
July 2003 Page 36 All rights reserved
Audit Trail Report Command Set
&%SAR$ Start Audit Record
&%SAR Lead in sequence
$ Command terminator
Marks the start of an audit record and begins a PJL job.. This command must be inserted in
the datastream after MICR Mode is entered and before the first flagged field appears. It
should be sent at the beginning of each check record.
End Audit Record &%STORE$
&%STORE Lead in sequence
$ Command terminator
Ends the Audit Record and the PJL job (ignored if there was no Start Audit Record
Command).
Audit Report Field One &%SQ1d..d$
&%SQ1 Lead in sequence
d..d Data to be stored
$ Command terminator
This command identifies the data to be printed in the first column of the report. It is a
maximum of 14 characters in length. If less than 14 characters are sent, the printer fills the
field with spaces when the audit report is printed. This field is recorded in the audit report
only, it is not printed on the check.
Audit Report Field Two-MICR Line &%SMDd..d$ or &%SM7d..d$
&%SMD or &%SM7 Lead in sequence
d..d Data to be printed
$ Command terminator
This command identifies the data to be printed in the second column of the report. It is a
maximum of 40 characters in length.
Audit Report Field Three &%SQ3d..d$
&%SQ3 Lead in sequence
d..d Data to be printed
$ Command terminator
This command identifies the data to be printed in the third column of the report. It is a
maximum of 40 characters.
Section 8: Audit Trail Reports