Audit Report Field Four &%SQ4d..d~
&%SQ4 Lead in sequence
d..d Data to be printed
~ Command terminator
This command identifies the data to be printed in the fourth column of the report. It is a
maximum of 16 characters in length. Since a total of this field can be provided at the end
of the Audit Trail Report it is typically used for the convenience amount field. NOTE: This is
the only command where the $ is not a command terminator. The tilde ~ (hex 7E) acts as
the command terminator.
Audit Report Field Five &%SQ5d..d$
&%SQ5 Lead in sequence
d..d Data to be printed
$ Command terminator
This command identifies the data to be printed in the fifth column of the report. This field is
a maximum of eight characters.
Audit Report Field Six &%SQ6d..d$
&%SQ6 Lead in string
d..d Data to be printed
$ Command terminator
This command identifies the data to be printed in the sixth column of the report. This field
is a maximum of 19 characters.
Audit Report Field Seven &%SQ7d..d$
&SQ&7 Lead in string
d..d Data to be stored
$ Command terminator
This command identifies the data to be printed in the seventh column of the report. This
field is a maximum of 12 characters. The data in this field is recorded for the Audit Report
only.