$ Command terminator
Ends the Audit Record and the PJL job (ignored if there was no Start Audit Record
Command).
Audit Report Field One &%SQ1d..d$
&%SQ1 Lead in sequence
d..d Data to be stored
$ Command terminator
This command identifies the data to be printed in the first column of the report. It is a
maximum of 14 characters in length. If less than 14 characters are sent, the printer fills the
field with spaces when the audit report is printed. This field is recorded in the audit report
only, it is not printed on the check.
Audit Report Field Two-MICR Line &%SMDd..d$ or &%SM7d..d$
&%SMD or &%SM7 Lead in sequence
d..d Data to be printed
$ Command terminator
This command identifies the data to be printed in the second column of the report. It is a
maximum of 40 characters in length.
Audit Report Field Three &%SQ3d..d$
&%SQ3 Lead in sequence
d..d Data to be printed
$ Command terminator
This command identifies the data to be printed in the third column of the report. It is a
maximum of 40 characters.
Audit Report Field Four &%SQ4d..d~
&%SQ4 Lead in sequence
d..d Data to be printed
~ Command terminator
This command identifies the data to be printed in the fourth column of the report. It is a
maximum of 16 characters in length. Since a total of this field can be provided at the end of
the Audit Trail Report it is typically used for the convenience amount field. NOTE: This is the
only command where the $ is not a command terminator. The tilde ~ (hex 7E) acts as the