Source Technologies ST9530 Printer User Manual


 
Secure MICR Printer User’s Guide © Source Technologies
September 2005
A14 All Rights Reserved
CARTRIDGE STATUS = UNKNOWN
= OK
= LOW
= EMPTY
CARTRIDGE SERIAL# = XXXXXXXX
TONER LEVEL = 0-9
= UNKNOWN
CARTRIDGE COUNT = XXXX
LOW THRESHOLD = XXXX
EMPTY THRESHOLD = XXXX
Printer State
o “Ready” is the expected return
Serial Number = Printer Serial Number
Page Count = Printer Page Count
Cartridge Type
o “MICR” is the expected return. “Normal” could mean the command was sent
to a non-MICR printer
Cartridge Status
o “OK, Low, and Empty” are the expected returns. “Unknown” is possible if the
cartridge had just been installed.
Cartridge Serial = Cartridge Serial Number
Toner Level
o A single digit return giving a rough estimate of toner remaining
o 9 = Full, 0 = Empty
Cartridge Count = xxxx
o Data indicating toner usage by counting pixels printed
Low Threshold = xxxx
o The Toner Low point based on cartridge count value
Empty Threshold = xxxx
o A cartridge count value that determines when printing must stop to ensure
quality MICR documents
PJL MICR Command Example
Figure 8.1, is an illustration of an Accounts Payable check and remittance information. The
page used a PCL MACRO for the static data and background design. This manual does not
address MACRO design and programming, but the variable text information including all
the PJL and PCL commands used to print the example are on the page following the
sample check. For illustrative purposes there are some extra spaces in the text preceding
the printable data. The following paragraphs describe the command functions. The
commands are a minimal set chosen to produce the example. Please consult Lexmark
Technical publications for the complete descriptions of PJL and PCL printer commands.