22
2.7 Install with IDR series
22 AWG UTP CABLE
CONVERTER
RS-232 CABLE
DATA1DATA2
DOME
R(T)X-
R(T)X+
WIRE CONNECTION
JUNCTION BOX
DOME1 +
DOME1 -
TX+(RS-485)
TX-(RS-485)
DOME2 +
DOME2 -
IDR SERIES
CONVERTER
JUNCTION BOX
J-BOX(REAR)
J-BOX(FRONT)
RS-232C to RS-485
Figure 11 – IDR Connection Diagram
If user wants to connect with IDR, please proceed as the following order.
1) Connect RS-232C cable between RS-232C Port of IDR and DVR port of the J-box. ( This
connection enables IDR control remotely from KBD controller)
2) Plug the RS-232C TO RS-485 converter in the RS-232C Port of IDR. Connect wires between
the TX(+/-) of converter and Data2(+/-) of J-Box.
(This connection enables IDR PTZ control from KBD controller)
3) How to setup the controller.
A. SWITCH THE KBD controller ON
B. INPUT PASSWORD (Factory Setting is 9999)
C. Open the menu of the KBD controller by pressing Ctrl + Menu
Key.
D. Set as below in Network menu.
Set Baud Rate
Dome : 9600
Mux : 9600
DVR485 : 9600
DVR232 : 9600
Com Ports
Dome : Dome
Mux : None
DVR485 : AUX IN
DVR232 : IDR
4) How to setup IDR