3.3.1 CONFIGURING THE 1686H, 1686V AND 1689 KEYPADS V2.0 OR HIGHER
The keypad’s zone number, EOL definition and tamper switch are programmed through the control panel’s
programming mode. To do so:
PLEASE NOTE: After two minutes, the keypad exits programming mode.
Key [1] - Keypad Zone Selection
Key [1] determines whether the keypad’s zone is Keypad Zone 1 or Keypad Zone 2. When key [1] is OFF
(not illuminated), the keypad’s zone is Keypad Zone 1. When key [1] is ON (illuminated), the keypad’s zone
is Keypad Zone 2.
Key [1] OFF - Keypad Zone 1 (default)
Key [1] ON - Keypad Zone 2
Key [2] - EOL Definition
Key [2] determines the keypad zone’s EOL definition. When key [2] is OFF (not illuminated), EOL is
disabled and the keypad zone will use the on-board EOL resistor. When key [2] is ON (illuminated), EOL is
enabled and the keypad zone requires that an external EOL resistor be connected (refer to Spectra
1738EX and 1738 Control Panel Overview on page 7 and Spectra 1728EX and 1728 Control Panel
Overview on page 8 for more details).
Key [2] OFF - EOL disabled
Key [2] ON - EOL enabled (default)
Key [3] - On-Board Tamper
Key [3] enables or disables the keypad’s on-board tamper switch. When key [3] is OFF (not illuminated),
the tamper switch is disabled. When key [3] is ON (illuminated), the tamper switch is enabled.
Key [3] OFF - On-board tamper switch disabled
Key [3] ON - On-board tamper switch enabled
PLEASE NOTE: The keypad can be ordered with or without a tamper switch. If the keypad has
no tamper switch, key [3] will be OFF by default. If the keypad has a tamper switch, key [3]
will be ON by default.
3.3.2 CONFIGURING THE 1686H, 1686V AND 1689 KEYPADS PRIOR TO V2.0
The keypad’s zone number and EOL definition are defined through the jumpers located on the PCB board.
The jumpers are as follows:
J1 - Keypad Zone Select Jumper
Jumper J1 determines whether the keypad’s zone is Keypad Zone 1 or Keypad Zone 2. When the jumper
is OFF, the keypad’s zone is Keypad Zone 2. When the jumper is ON, the keypad’s zone is Keypad Zone 1.
J1 OFF - Keypad Zone 2
J1 ON - Keypad Zone 1
How Do I Configure The Keypad?
STEP 1: Press
[ENTER]
STEP 2: Enter your [INSTALLER CODE] (default: 000000 or 0000)
STEP 3: Press the
[PG] (1686H/V) / [FNC1] (1689) key and hold it for 3 seconds.
STEP 4: Press the desired key ([1] to [3]. See below)
STEP 5: Press [
ENTER] to exit programming mode