SpectraLink 1738 Computer Hardware User Manual


 
22 REFERENCE & INSTALLATION MANUAL
5.5.2 ENTRY DELAY 2
Sections [001] to [016]: Zones 1 to 16, First Digit = 2
Entry Delay 2 zones are identical to the Entry Delay 1 zones (see section 5.5.1), except it uses a separate
Entry Delay Timer. To program the Entry Delay 2 Timer, key in the desired 3-digit delay value (000 to 255
seconds, Default = 45 seconds) into section [070].
This timer is also used as the Stay Delay timer (see section 6.2).
5.5.3 FOLLOW ZONES
Sections [001] to [016]: Zones 1 to 16, First Digit = 3
When an armed Follow Zone opens, the control panel will immediately generate an alarm, unless an Entry
Delay zone opens first:
If an armed Follow Zone opens after an Entry Delay zone opens, the control panel waits until the Entry
Delay Timer has elapsed before generating an alarm.
If an armed Follow Zone opens after more than one Entry Delay zone opens, the control panel will wait
until the Entry Delay Timer of the zone that opened first has elapsed.
This feature is commonly used when a motion detector is protecting the area occupied by the entry point
keypad. This will prevent the motion detector from causing an alarm when a user enters through the entry
point to disarm the system.
5.5.4 INSTANT ZONES
Sections [001] to [016]: Zones 1 to 16, First Digit = 4
When an armed Instant Zone opens, the control panel immediately generates an alarm. Instant Zones are
commonly used for windows, patio doors, skylights and other perimeter type zones.
5.5.5 24HR. BURGLARY ZONES
Sections [001] to [016]: Zones 1 to 16, First Digit = 5
Whenever a 24Hr. Burglary Zone opens, whether the system is armed or disarmed, the control panel will
immediately generate an alarm.
5.5.6 24HR. BUZZER
Sections [001] to [016]: Zones 1 to 16, First Digit = 6
Whenever a 24Hr. Buzzer Zone opens, whether the zone is armed or disarmed, the control panel sets off
the keypads’ buzzers to indicate that the zone was breached. The control panel will report the alarm, but
will not enable the bell/siren output. Enter any valid access code on the keypad to stop the buzzer. This
zone definition is particularly useful when a user wishes to be notified when something such as a safe or
locker within the home has been accessed (i.e. a child accessing a valuable collection).
5.6 EXCLUSIVE ZONE DEFINITIONS
The following three zone definitions can only be used for devices connected directly to the control panel’s on-board
input terminals. When a zone is programmed as a Keyswitch Zone, the control panel will ignore all other Zone
Options. When a zone is programmed as a Standard Fire Zone or Delayed Fire Zone, the control panel will ignore
the Zone Options that may have been programmed, except Auto Zone Shutdown. Wireless devices and devices
connected to the zone expansion bus modules cannot be programmed with these definitions.
5.6.1 KEYSWITCH ZONE
1728/EX: Sections [001] to [004]: Zones 1 to 4, First Digit = 7
1738/EX: Sections [001] to [007]: Zones 1 to 7, First Digit = 7
Connecting a keyswitch to a zone allows users to arm the system by pressing a button or by turning a
switch on or off with a key. Please refer to Keyswitch Connections on page 13 and to Keyswitch Options on
page 25.
If the ATZ feature is enabled when using a Keyswitch, the control panel will disable the
“doubled zone” (see Zone Doubling on page 25).