SPECTRA SERIES 33
8.1 REPORTING/DIALER (ENABLE/DISABLE)
Section [135]: Dialer Options
Option [3] OFF = Reporting/Dialer Disabled (default)
Option [3] ON = Reporting/Dialer Enabled
8.2 REPORT CODES
A report code is a 1- or 2-digit hexadecimal value consisting of digits from 1 to F. Each section from [160] to [213]
represents a set of up to four specific events and each of these events can be programmed with a separate 1- or 2-
digit report code.
Only the Ademco Slow, Silent Knight, Sescoa and Pager Formats support 1-digit report codes. To
program a 1-digit report code, press the [
FORCE] key followed by the desired hexadecimal digit or
vice versa.
When a specific event occurs, the control panel will attempt to transmit the programmed report code to the central
station. The method of report code transmission is defined by the Reporting Formats (see page 36) and the Event
Call Direction (see page 38). These two items define how and where the report codes are transmitted. If you are
using the Ademco Contact ID “All Codes” format, sections [160] to [213] do not have to be programmed. For more
information, refer to Reporting Formats (see page 36). The following sub-sections provide a brief description of the
events that the control panel can report.
8.2.1 ARMING REPORT CODES
Sections [160] to [171]
A report code can be programmed for each of the 48 User Access Codes. When using an access code to
arm a partition, the control panel can send the appropriate report code to the central station, identifying
which access code was used to arm the partition.
8.2.2 SPECIAL ARMING REPORT CODES
Sections [172] and [173]
Whenever the system is armed using one of the special arming features listed below, the control panel can
send the appropriate report code to the central station identifying how the system was armed.
Section [172]
•
TIMED AUTO-ARMING: A partition has armed itself at the programmed time (see page 28).
•
LATE TO CLOSE: Reports every day at the time specified by the Auto-Arm Timer (see page 28).
•
NO MOVEMENT: A partition has armed itself after the programmed period without movement (see No
Movement Arming on page 28).
•
PARTIAL ARMING: A partition was Stay, Instant or Force Armed or armed with Bypassed zones.
Section [173]
•
ONE-TOUCH ARMING: A partition was armed using a One-touch Arming feature (see page 29).
•
REMOTE ARMING: A partition was armed using the Winload software.
•
KEYSWITCH ARMING: A partition was armed using a keyswitch (see page 22)
• Future use
8.2.3 DISARMING REPORT CODES
Sections [174] to [185]
A report code can be programmed for each of the 48 User Access Codes. Whenever an access code is
used to disarm an armed partition or a partition in alarm, the control panel can send the appropriate report
code to the central station, identifying which access code was used to disarm the partition.
The Disarming and the Special Disarming report codes can be transmitted every time a partition is
disarmed or only when a partition is disarmed after an alarm (see Disarming Reporting Options on
page 40).