Star Micronics Line Thermal Printer Printer User Manual


 
―――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――――
STAR Line Mode Command Specifications 5-6
5.2. Appendix 2: Status Specifications
5.2.1. ENQ Command Status
This status is the one the printer transmits using the ENQ command.
Bit Contents Status Model Compatability
“0” “1”
TSP800 TSP700 TSP600 TUP900 TSP1000 TSP828L TSP700II TSP650
7 Conversion SW OPEN CLOSE OK OK OK No NO NO OK OK
6 Overrun Error No Yes OK OK OK OK OK OK OK OK
5 Reception Buffer Empty Has Data Empty OK OK OK OK OK OK OK OK
4 Fixed at ”0” - - - - - - - - -
3 Paper end Paper No Paper OK OK OK OK OK OK OK OK
2 Other Errors No Yes OK OK OK OK OK OK OK OK
1 Framing Error No Yes OK OK OK OK OK OK OK OK
0 Parity Error No Yes OK OK OK OK OK OK OK OK
• Overrun errors/Framing errors/Parity errors
These errors occur when using a serial I/F.
These errors are after holding the error and using this command to inquire the status and the error status is sent.
• Other Errors
Indicates non-recoverable errors and cover open errors.
5.2.2. EOT Command Status
This status is the one the printer transmits using the EOT command.
Bit Contents Status Model Compatability
“0” “1”
TSP800 TSP700 TSP600 TUP900 TSP1000 TSP828L TSP700II TSP650
7 Compulsion SW OPEN CLOSE - OK OK OK - - - OK OK
6 Presenter Paper Jam Error No Yes No No No OK No NO NO NO
5 Paper Near-end (Outer Side) Paper No Paper No No No No No NO NO NO
4 Fixed at “1” - - - - - - - - -
3 Paper end Paper No Paper OK OK OK OK OK OK OK OK
2 Paper Near-end (Inner Side) Paper No Paper OK OK OK OK OK NO OK OK
1 BINDING MEDIA Error No Yes No No No OK OK OK OK NO
0 Fixed at “0” - - - - - - - - -
• BM Error
On models that use a common PE and BM sensor, if a continuous error is detected beyond a determined amount, it
indicates not a black mark error, but a paper out error.