Sun Microsystems 4500/3 Network Router User Manual


 
Chapter 2 The Cluster Platform 4500/3 System 23
The terminal concentrator opens an editing session and displays an editing
config.annex file.
9. Type the following information into the config.annex file; replace the following
variable with the IP address obtained from your network administrator.
10. Enter the
<ctrl>w command to save changes and exit the config.annex file.
11. Enable access to all ports, and reboot the terminal concentrator.
Note After 90 seconds, the terminal concentrator and all ports will be accessible
from outside the subnet. Use the command
usr/sbin/ping -I 5 148.212.87.62
to determine when the terminal concentrator is ready to be used.
Caution The following steps display critical information for configuring the
cluster nodes. Use the “Ethernet IP Address Worksheet” on page 8 to collect the
Ethernet addresses. Consult your system administrator to obtain the IP addresses
and node names for your cluster devices.
Note Make sure all network interfaces for node 1 and node 2 are attached to the
production network. (See Figure 2-3 on page 12 for connection details.)
%gateway
net default gateway 148.212.87.248 metric 1 active
Ctrl-W: save and exit Ctrl-X: exit Ctrl-F: page down Ctrl-B:
page up
annex# admin
Annex administration MICRO-XL-UX R7.0.1, 8 ports
admin: port all
admin: set port mode slave
You may need to reset the appropriate port, Annex subsystem
or reboot the Annex for changes to take effect.
admin: quit
annex#: boot
bootfile: <CR>
warning: <CR>
*** Annex (148.212.87.62) shutdown message from port v1 ***
Annex (148.212.87.62) going down IMMEDIATELY