2-2 Netra CP32x0 SAS Storage Advanced Rear Transition Module HD User’s Guide • January 2009
2.1 About Installing and Removing the
ARTM-HD
The ARTM-HD can be installed into an ATCA shelf (chassis) with a midplane made
for front and rear board installations (
FIGURE 2-1). The module must be installed in
the slot directly behind the Netra ATCA node board. These back-to-back slots have
common pins to enable passing of signals.
Note – Connectors on previous blade servers do not mate with connectors on the
ARTM-HD.
Before installing the ARTM-HD, verify the module’s part number to ensure that the
correct ARTM-HD is being installed into the system. For information on identifying
the ARTM-HD, see Section 1.10, “Part Number, Serial Number, and FC Address
Labels” on page 1-13.
Caution – Use the ARTM-HD only with compatible blade servers. Attempts to
install the ARTM-HD with an incompatible blade server might cause damage to
themselves and the blade server.