Sun Microsystems X4150 Server Computer Drive User Manual


 
32 Sun Fire X4150 Installation Guide January 2008
Cabling the Server
Connect the server power cables, and external cables in the following order:
1. Connect two grounded server power cords to grounded electrical outlets (1, 2).
Note Connect only one cable if your server does not have a redundant power
supply.
2. Connect the two server power cords to the AC power connectors on the back panel
of the server.
In standby power mode, the Power/OK LED on the front panel flashes, indicating
that the service processor (SP) is working as shown in FIGURE 3-2. At this point, before
initial configuration, standby power is supplied only to the SP and power supply fans.
FIGURE 3-2 Front Panel Power/OK LED
Note Do not push the Power button at this time. Do not apply main power to the rest
of the server until you are ready to install a platform operating system.
3. Connect a serial null modem cable to the RJ-45 serial port (4).
See “Connecting to the Embedded LOM Service Processor for the First Time” on
page 33 for more information about viewing system output from a serial console.
4. Connect Ethernet cables to the Embedded LOM SP network management Ethernet
port (5).
5. Connect Ethernet cables to the RJ-45 LAN Gigabit Ethernet (LAN) connectors as
needed (6) for OS support.
6. Connect any additional external devices, as required, to the server’s USB (7)
and/or Video (8) connectors (optional).
7. Go to the next section and connect to the Embedded LOM SP.