Symbol Technologies DS6708 Scanner User Manual


 
Appendix A: Standard Default Parameters A - 7
Transmit US Postal Check Digit 5Fh Enable 13-48
RSS (Reduced Space Symbology)
RSS 14 F0h 52h Enable 13-49
RSS Limited F0h 53h Enable 13-49
RSS Expanded F0h 54h Enable 13-50
Convert RSS to UPC/EAN F0h 8Dh Disable 13-50
Composite
Composite CC-C F0h 55h Disable 13-51
Composite CC-A/B F0h 56h Disable 13-51
Composite TLC-39 F0h 73h Disable 13-52
UPC Composite Mode F0h 58h Always Linked 13-52
Composite Beep Mode F0h 8Eh Beep As Each Code Type is
Decoded
13-53
UCC/EAN Code 128 Emulation Mode for
UCC/EAN Composite Codes
F0h ABh Disable 13-53
2D Symbologies
PDF417 0Fh Enable 13-54
MicroPDF417 E3h Disable 13-54
Code 128 Emulation 7Bh Disable 13-55
Data Matrix F0h 24h Enable 13-56
Maxicode F0h 26h Enable 13-56
QR Code F0h 25h Enable 13-57
Symbology-Specific Security Levels
Redundancy Level 4Eh 1 13-57
Security Level 4Dh 1 13-60
Intercharacter Gap Size F0h 7Dh Normal 13-61
Report Version 13-61
Table A-1
Standard Default Parameters Table (Continued)
Parameter
Parameter
Number
Default
Page
Number
1
User selection is required to configure this interface and this is the most common selection.