Symbol Technologies DS6708 Scanner User Manual


 
7 - 4 DS6708 Digital Scanner Product Reference Guide
RS-232 Host Parameters
Various RS-232 hosts are set up with their own parameter default settings (Table 7-2). Selecting standard, ICL,
Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron sets the defaults
listed below.
Table 7-2
Terminal Specific RS-232
Parameter ICL Fujitsu
Wincor-Nixdorf
Mode A
Wincor-Nixdorf
Mode
B/OPOS/JPOS
Olivetti Omron
Transmit Code ID Yes Yes Yes Yes Yes Yes
Data Transmission
Format
Data/Suffix Data/Suffix Data/Suffix Data/Suffix Prefix/Data/
Suffix
Data/Suffix
Suffix CR (1013) CR (1013) CR (1013) CR (1013) ETX (1002) CR (1013)
Baud Rate 9600 9600 9600 9600 9600 9600
Parity Even None Odd Odd Even None
Hardware
Handshaking
RTS/CTS
Option 3
None RTS/CTS
Option 3
RTS/CTS
Option 3
None None
Software
Handshaking
None None None None Ack/Nak None
Serial Response
Time-out
9.9 Sec. 2 Sec. 9.9 Sec. 9.9 Sec. 9.9 Sec. 9.9 Sec.
Stop Bit Select One One One One One One
ASCII Format 8-Bit 8-Bit 8-Bit 8-Bit 7-Bit 8-Bit
Beep On <BEL> Disable Disable Disable Disable Disable Disable
RTS Line State High Low Low Low = No data
to send
Low High
Prefix None None None None STX (1003) None
* In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes.
**If Nixdorf Mode B is scanned without the digital scanner connected to the proper host, it may appear unable to scan.
If this happens, scan a different RS-232 host type within 5 seconds of cycling power to the digital scanner.