6 - 10 DS6708 Digital Scanner Product Reference Guide
Function Key Mapping
ASCII values under 32 are normally sent as a control-key sequences (see Table 6-2 on page 6-12). When this
parameter is enabled, the keys in bold are sent in place of the standard key mapping. Table entries that do not
have a bold entry remain the same whether or not this parameter is enabled.
Simulated Caps Lock
When enabled, the digital scanner inverts upper and lower case characters on the bar code as if the Caps Lock
state is enabled on the keyboard. This inversion is done regardless of the current state of the keyboard’s Caps
Lock state.
*Disable Function Key Mapping
Enable Function Key Mapping
*Disable Simulated Caps Lock
Enable Simulated Caps Lock