Symbol Technologies DS6708 Scanner User Manual


 
4 - 2 DS6708 Digital Scanner Product Reference Guide
Scanning Sequence Examples
In most cases, scanning one bar code sets the parameter value. For example, to set the beeper tone to high,
scan the High Frequency (beeper tone) bar code listed under Beeper Tone on page 4-5. The digital scanner
issues a fast warble beep and the LED turns green, signifying a successful parameter entry.
Other parameters, such as Serial Response Time-Out or Data Transmission Formats, require scanning
several bar codes. See these parameter descriptions for this procedure.
Errors While Scanning
Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
User Preferences/Miscellaneous Options Parameter Defaults
Table 4-4 lists defaults for user preferences parameters. There are two ways to change the default values:
Scan the appropriate bar codes in this guide. These new values replace the standard default values in
memory. To recall the default parameter values, scan the Set Default Parameter on page 4-4.
Configure the digital scanner using the 123Scan configuration program (see Chapter 12, 123Scan).
NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies,
and miscellaneous default parameters.
Table 4-4
User Preferences Parameter Defaults
Parameter
Paramete
r Number
Default
Page
Number
User Preferences
Set Default Parameter All Defaults 4-4
Parameter Scanning ECh Enable 4-4
Beeper Tone 91h Medium 4-5
Beeper Volume 8Ch High 4-6
Power Mode 80h Continuous On 4-6
Time Delay to Low Power Mode 92h 1 Minute 4-7
Trigger Mode 8Ah Auto Aim 4-8
Picklist Mode F0h 92h Disabled Always 4-9
Decode Session Timeout 88h 9.9 Sec 4-10
Timeout Between Decodes, Same
Symbol
89h 0.6 Sec 4-10