Symbol Technologies DS 3408 Scanner User Manual


 
DS 3408 Product Reference Guide4-10
Decode Session Timeout
Parameter # 88h
This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second
increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds.
To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from Appendix D, Numeric Bar Codes
that correspond to the desired on time. Single digit numbers must have a leading zero. For example, to set a Decode Session Timeout
of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar codes. To correct an error or change the selection, scan Cancel
on page D-4.
Timeout Between Decodes, Same Symbol
Parameter # 89h
This option is used in hands-free (Intellistand) mode to prevent the beeper from continuously beeping when a symbol is left in the
digital scanner’s field of view. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds. The default interval is 0.6 seconds.
To select the timeout between decodes for the same symbol, scan the bar code below, then scan two numeric bar codes from
Appendix D, Numeric Bar Codes that correspond to the desired interval, in 0.1 second increments.