RS-232 Interface 7-7
RS-232 Host Parameters (continued)
Selecting ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, or Omron enables the transmission of
code ID characters listed in Table 7-3. These code ID characters are not programmable and are separate from the Transmit Code ID
feature. Do not enable the Transmit Code ID feature for these terminals.
Table 7-3. Terminal Specific Code ID Characters
ICL Fujitsu
Wincor-
Nixdorf
Mode A
Wincor-
Nixdorf
Mode B/
OPOS/JPOS
Olivetti Omron
UPC-A AAAAAA
UPC-E EECCCE
EAN-8/JAN-8 FFFFBBBFF
EAN-13/JAN-13 FFAAAF
Code 39 C <len> None M M M <len> C <len>
Codabar N <len> None N N N <len> N <len>
Code 128 L <len> None K K K <len> L <len>
I 2 of 5 I <len> None I I I <len> I <len>
Code 93 None None L L L <len> None
D 2 of 5 H <len> None H H H <len> H <len>
UCC/EAN 128 L <len> None P P P <len> L <len>
MSI None None O O O <len> None
Bookland EAN FF AAAF
Trioptic None None None None None None
Code 11 None None None None None None
IATA H<len> None H H None None
Code 32 None None None None None None