3-2
PDT 1100 Terminal DLL Guide
Setting up the PDT 1100 in System Mode
Hold down the SF and 1 keys to power on the PDT 1100.
Setting Communications Parameters
The table below lists the default communications parameter values:
To modify the above settings, set the desired values on the System Environment Setting screen
in System Mode. For details, refer to the PDT 1100 Product Reference Guide.
Select the PDT 1100-Ir protocol in the PDT 1100 when using Ir-Transfer Utility C and E DLL.
The PDT 1100-Ir protocol automatically adds the serial number and horizontal parity, so
other settings made in the PDT 1100 are ignored.
To download data files to the PDT 1100 using +C option specified in the DLL, select [Data]
on the Communications Protocol Option screen in System Mode to treat space codes in the
tail of a data field as data. If you have selected the +C option, every record in a data file should
be fixed in length (refer to Data Files on page 2-4) so that space codes used to fill blanks in
the tail of a data field are data, not characters.
Downloading
Use the download menu in System Mode to download files. For details, refer to the PDT
1100 Product Reference Guide.
Table 3-1. Communications Parameter s
Communications parameters Defaults
Transmission speed 9600 bps
Output pulse width of IR beam 1.63 us
Serial number ON
Horizontal parity ON
Timeout for link establishment 30 seconds
Space codes in the tail of a data field Ignore
Communications protocol PDT 1100-protocol
Interface Optical