SysKonnect SK-54C1 Network Card User Manual


 
SysKonnect SK-54C1 Wireless LAN Cardbus Adapter
6 Troubleshooting
Removing incomplete Installations
When inserting the SysKonnect SK-54C1 Wireless LAN Cardbus Adapter into the computer
and before running the SysKonnect installation software from the SysKonnect CD-ROM, Win-
dows will detect the new hardware and attempt to install a driver for it. To guarantee installa-
tion of the correct driver and the Marvell Configuration Utility software, insert the SysKonnect
CD-ROM and complete the installation of the Marvell Configuration Utility before installing the
adapter.
Adapter installed, Marvell Configuration Utility
not found
The Marvell installation package installs both the Marvell Configuration Utility and the Win-
dows driver. The Marvell Configuration Utility is accessed by double-clicking the M
ARVELL LIB-
ERTAS CLIENT CONFIGURATION MANAGER icon in the system tray. It is also accessed through
the P
ROGRAMS menu.
The Marvell Configuration Utility will only function properly if prior to the setup the adapter is
installed properly. When the adapter is inserted and then the Marvell Configuration Utility is
called without installing the Windows driver, the Marvell Configuration Utility will be installed
but some of the tabs will be disabled and the L
INK INFORMATION status will indicate Card Un-
plugged or Not Connected.
To install the Marvell Configuration Utility after the adapter has already been installed under
Windows:
1. Verify that no previous version of the Marvell Configuration Utility is present on your sys-
tem. Use A
DD/REMOVE PROGRAMS in the Control Panel.
If any version of the Marvell Configuration Utility is listed, highlight it and click R
EMOVE.
2. In the Device Manager, with the adapter inserted, verify that the adapter is listed.
If the adapter is not listed in the Device Manager, do not continue with these steps.
Instead, reboot the computer and install the adapter driver and the Marvell Configuration
Utility according to the installation instructions provided in this manual.
If the adapter is listed, proceed with step 3 to install the Marvell Configuration Utility.
3. Insert the SysKonnect CD-ROM into your CD-ROM drive.
4. Click E
XIT on the SysKonnect screen that appears (the adapter is already installed (do
not run the SysKonnect installation software)).
5. Double-click M
Y COMPUTER or select START > MY COMPUTER.
6. Right-click the CD-ROM drive containing the SysKonnect CD-ROM.
7. Click E
XPLORE.
8. Make sure that the adapter is inserted.
9. Find the file PROSet.msi in the root of the SysKonnect CD-ROM.
10. Double-click it, and follow the prompts.
11. In the window “Setup Type”, select Typical.
12. Click N
EXT.
13. Click I
NSTALL.
14. Once the installation is complete, double-click the M
ARVELL LIBERTAS CLIENT CONFIGURA-
TION MANAGER icon in the system tray.
15. If the Marvell Configuration Utility does not detect the adapter, see section “Uninstalling
earlier Versions of the Marvell Configuration Utility” on page 56.