Telex ISP-100 Network Card User Manual


 
4-9
Specifications
Performance
(Sample Rate Converter bypassed)
Symbol Description Minimum Typical Maximum Units
F
s
Sample Rate for Digital TBD 48 96 kHz
Input Data
19
THD+N Total Harmonic Distortion 0.00002 %
plus Noise
20
(RELATIVE)
IMD Intermodulation Distortion
21
0%
(SMPTE 4:1)
Jitter in Output Clock 415 pS
Tolerable Jitter in Input 35 nS
Clock before Loss of Lock
22
Resolution (input) 24 24 bits
Resolution (output) 24 24 24 bits
Frequency Response
23
+/-0 dB
Dynamic Range
24
Equal to Dynamic Range dB
of input signal
Noise Floor
25
Equal to Noise Floor dB
of input signal
Delay through receiver
26
2 WSR+periods
Delay through transmitter
27
43
/
64
WST+periods
Interchannel Phase Deviation
28
0 Degrees
MCLK+ Master Clock
29
TBD 12.288 24.576 MHz
WSR+ Receive Word Clock
30
(MCLK+)/256 Hz
WST+ Transmit Word Clock
31
(MCLK+)/256 Hz
SCKR+ Receive Bit Clock
32
(MCLK+)/4 Hz
SCKT+ Transmit Bit Clock
33
(MCLK+)/4 Hz
Z
in
Input Impedance 110 Ohms
Z
out
Output Impedance 110 Ohms
Miscellaneous
Overall Size: 8.40" long by 2.55" wide by 1.50" high
Weight: 3.8 Ounces
Input Connector: 3 Pin standard female XLR
Output Connector: 3 Pin standard male XLR
XLR pinout: Pin 1 shield, Pin 2 positive input, Pin3 negative input.
Input Data Format: AES/EBU (AES3) Professional and S/PDIF. (IEC958) Consumer data formats are automatically identified and
correctly decoded.
Output Data Format: AES/EBU Professional, regardless of input data format.
De-emphasis: Not implemented; emphasis information from Channel Status Bits is relayed to host via Serial Peripheral
Interface (SPI).
Mutes: Linked Left and Right input mute selectable via SPI control; linked Left and Right output mute selectable via
SPI control.
Serial Data Interface: TBD
Synchronous Sampling: Multiple outputs may be synchronized via DPDB signal on connector. MDM-1 transmitter is slaved to MCLK+,
WST+, and SCKT+ signals. MDM-1 receiver may be configured as Master, to generate MCLK+ (via AES_CLK),
WSR+, and SCKR+ signals derived from input data stream, or as Slave, to receive WSR+ and SCKR+ signals
from card-edge connector, either with or without the Sample Rate Converter. With sample rate converter
engaged, the MDM-1 cannot be configured as the master.
Unless otherwise noted:
Signal measurements are at unity gain, +16 dBu and 20 Hz to 20 kHz bandwidth.
Power measurements are quiescent.
Operating temperature with non condensing humidity