NOTE: Typically, metal halide lamps have an average operating life of
approximately 2,000 hours. When the On-Screen
LAMP HOURS
shows
2,000 hours of operation, lamp failure may occur soon. You may elect to
replace the lamp, or continue using your P350 until the lamp actually fails.
5. Loosen the two lamp compartment screws shown in Figure 14.
(These are captive screws and should not be completely removed.)
6. Lift out the lamp compartment assembly.
7. Install a new lamp compartment assembly.
8. Tighten the two lamp compartment screws shown in Figure 14.
Fuse Replacement
Figure 15 shows the location of the fuse holder. Use a small flat-blade
screwdriver to pop the fuse holder out.
NOTE: To access the fuseholder, the Firefly™ P350 must be in its
raised position with the power cord unplugged.
Replace the fuses only with the type and rating shown on the label. If the
module repeatedly blows fuses, return it for servicing.
Use only with a 250V fuse
Employer uniquement avec
un fusible de 250V
FUSE
HOLDER
AC POWER
INPUT JACK
Figure 15. Fuseholder Location
☞
☞