4.4.3 Manual Restart
Manual RestartManual Restart
Manual Restart
The administrator can reboot the RamSan manually from the front
panel display. This procedure safely synchronizes all data in RAM to
the internal Flash module storage, powers off for around 5 seconds,
and then powers back on.
Main Menu
Manual Restart
To shut down the system using
the front panel, use the arrow
buttons to cycle through the
top-level menu to select
Manual Restart”. Use the
Select button to select this
menu item.
Restart System?
Yes No
The display prompts you to
confirm that you wish to
Restart System”. To cancel
the shutdown, use the
button
to return to the main menu. To
proceed with the shutdown,
use the
button to confirm the
system power off.
Powering Off 90%

Now, the front panel display
indicates that the system is
powering off. When the
system is ready, it will
automatically shut off. In
approximately 5 seconds time,
the system will turn back on.
4.4.4
4.4.44.4.4
4.4.4 Automatic
Automatic Automatic
Automatic S
SS
Shutdown
hutdownhutdown
hutdown
In the event that the system senses a high system temperature,
power out of range, or a variety of other dangerous environmental
conditions, the system will automatically initiate the shutdown
procedure.
4.5 Network Configuration with the Front Panel Display
The RamSan-500 allows system monitoring and configuration through the
installed Ethernet module. To access the system’s Ethernet port you will
need to provide the system with an IP address, subnet mask, and possibly
a gateway address. The administrator may assign the IP address in one of
three ways: Static IP, DHCP, or No Ethernet. The default factory setting is
DHCP.
For any questions regarding IP assignment values, please consult your
network administrator.