Syringe Mode
The Syringe mode enables all stations with a programmed run time in a selected program to be operated for
a short, temporary run time (syringe). The amount of run time for the syringe operation can be set from
1 – 30 minutes
or by a percentage of programmed station run time from 10% – 99%.
To syringe all stations from 1 – 30 minutes:
1. Press to select Syringe indicator.Program 1 will be
automatically selected .
2. Press or to select desired Program number (1 – 16).
The Left display shows the program number and
rt (run time in
minutes). A 1-minute syringe time is automatically selected and shown
in the right display. To increase the syringe run time, continue at step 3.
If no increase is needed, continue at step 5.
3. Press – The syringe time digits will begin flashing.
4. Press or to select a syringe time (02 – 30 minutes).
5. Press to start the syringe cycle. The displays will alternate
between the time/day and the program status.
Note: Only the stations with a programmed run time in the program
selected will operate during the syringe operation.
To syringe from 10% – 99% of station run time:
1. Repeat steps 1 and 2 above.
2. Press The left display shows a % symbol. A 25% adjusted run
time value is automatically selected and shown in the right display.
To change the % value, continue at step 4; if no change is needed,
continue at step 6.
3. Press – Syringe % value (25%) will begin flashing.
4. Press or to adjust run time value from 10% – 99%.
5. Press to start the syringe cycle. The displays will alternate
between Time/Day and program status as shown above.
Note: When the station run time remaining becomes less than one
minute, the display will show 00. The display will continue to show 00
while the remaining time of 59 seconds or less elapses.
ENTER
START
ENTER
START
11
:
AM
:
Fr
:
:
:
:
:
:
:
:
Station
Number
Syringe
Time
Remaining
Syringe
Run Time
Program
Number
Program
Number
Program
Number
Run Time In
Minutes
Run Time By
Percentage
25%
Adjusted Run
Time % Value