2. MAJOR UNIT REPLACEMENT
EO18-33018
2.4 Replacing the Panel PC Board
2-7
5) Remove the two PT-3x6 screws and W-4 washers to detach the panel PC board from the operation
panel cover.
6) Replace the panel PC board with a new one, then reassemble in the order removal.
7) Turn the power on, then confirm that the LCD message is displayed properly.
Operation Panel Cover
E Plate
Key Switch
Panel PC Board
W-4
W-4
PT-3x6 Screw
Flat Cable