Toshiba B-SA4TM-TS12-QM-R Printer User Manual


 
2. PRINTER SETUP ENGLISH VERSION EO1-33047
2.4 Loading the Ribbon
E2-12
2.4 Loading the Ribbon
(Cont.)
3. Lower the Top Cover to its 45
° angle open position. While pushing
the Top Cover Stopper, raise the Top Cover again. This will fix the
Top Cover.
4. Open the Ribbon Cover.
5. Fit the ribbon take-up core into the Ribbon Holder (Take-up side),
aligning the notch of the ribbon core with the protrusion of the Ribbon
Stopper.
6. Turn the ribbon take-up core in the direction indicated by the arrow to
remove any slack.
NOTES:
1. Be sure to remove any slack in
the ribbon when printing.
Printing with a wrinkled ribbon
will lower the print quality.
2. When a ribbon end is detected,
“RIBBON ERROR” message
will appear on the display and
the ERROR LED will illuminate.
3. When disposing of the ribbons,
please follow the local rules.
4. For the specification of
available ribbon, refer to
Section 7.2 Ribbon.
Ribbon Cover
Ribbon Holder
(Take-up side)
45°
Top Cover
Top Cover
Stopper