Toshiba B-SA4TM-TS12-QM-R Printer User Manual


 
2. PRINTER SETUP ENGLISH VERSION EO1-33047
2.7 Setting an Operating Environment
E2-22
2.7.1 Parameter Setting
(Cont.)
When ON is selected, pressing the [PAUSE] key will result that the LCD
Message Display shows the stop position fine adjustment value setting
screen.
[FEED] key: Pressing the [FEED] key one time causes a –0.1mm change,
up to –5.0 mm.
[RESTART] key: Pressing the [RESTART] key one time causes a +0.1mm
change, up to +5.0 mm.
After selecting an auto forward wait, press the [PAUSE] key.
(10) Control Code Selection
This parameter is to choose a Control Code.
When “<2>PARAMETER SET” appears, press the [PAUSE] key until
the following display appears.
Use the [FEED] or [RESTART] key to select a desired option.
When “CODE MANUAL” is selected and the [PAUSE] key is pressed,
the LCD display will show the setting screen of CONTROL CODE1 to
CONTROL CODE3 as follows.
POSITION +5.0mm
POSITION +0.0mm
[RESTART]
[FEED]
POSITION -5.0mm
<2>PARAMETER SET
POSITION +0.0mm
<2>PARAMETER SET
CODE AUTO
CODE AUTO
CODE ESC,LF,NUL
[RESTART]
[FEED]
CODE{|}
CODE MANUAL
Automatic selection
Manual selection
Manual selection
Control codes should
be specified.
<2>PARAMETER SET
CONTROL CODE1 1B
[RESTART]
[FEED]
CONTROL CODE1 FF
CONTROL CODE1 FE
CONTROL CODE1 01
CONTROL CODE1 00
CONTROL CODE1 FD
CONTROL CODE1 02