Toshiba EO1-33087 Barcode Reader User Manual


 
APPENDIX 1 SPECIFICATIONS ENGLISH VERSION EO1-33087
A1.3 Media
EA1- 5
A1.3.3 Detection Area of the Reflective Sensor
The Reflective Sensor is movable within the full range of the media width.
The reflection factor of the Black Mark must be 10% or lower with a waveform length of 950 nm.
The Reflective Sensor should be aligned with the centre of the Black Mark.
A1.3.4 Effective Print Area
The figure below illustrates the relation between the head effective print width and media width.
(for GS14 Type)
(for TS14 Type)
Min. 2 mm
Min. 8 mm
Sensor should be positioned at the
centre of the black mark.
Media feed direction
Detecting the black marks on the
back.
Sensor is movable within the full range.
2 mm
112.0 mm (Max. media width)
108.0 mm
±
0.2mm
(Head Effective Print Range)
Out of print range
Out of print range
2 mm
Print head element
3 mm
112.0 mm (Max. media width)
106.0 mm
±
0.2mm
(Head Effective Print Range)
Out of print range
Out of print range
3 mm
Print head element