Toshiba ES96R Network Card User Manual


 
Specifications
ONEAC 400 UPS
Stratagy General Description 01/03 55
Table 6 Stratagy Hardware Environmental and Electrical Specification Summary
Environmental
Conditions
Operating Temperature
39.2ºF~104ºF (4ºC~40ºC)
Storage Temperature
104
ºF~140ºF (40ºC~60ºC)
Operating Humidity 20%~80% (non-condensing)
Electrical
Requirements
(AC Input)
Stratagy Enterprise Server (ES) 115VAC, at 6 amps (50/60 Hz) standard
230VAC at 3.5 amps (50/60 Hz) switch configured
Optional Monitor 115VAC at 0.5 amps (50/60 Hz)
Provide host system with 15A circuit breaker and dedicated circuit.
Heat Dissipation
Stratagy Enterprise Server (ES) Maximum 200 watts, 685 BTU per hour
Optional Monitor Maximum 50 watts, 200 BTU per hour
Analog Interface
Telco types Loop Start, OPX, T1
Connection Single line, RJ14C and RJ11C jacks; RJ48C (T1)
Impedance 600 ohm nominal
Frequency response 300~3200 Hz
Ring detect 40~130 Vrms, 15.3~68.0 Hz
Loop current range 20~120 mA polarity insensitive
Transfer signaling Hookflash
Input level -30 dB~-3 dB
Output level -30 dB~-3 dB
DTMF receive
Minimum tone duration
Minimum tone detect
Twist range
16 tones (0~9,
*
, #, A~D)
45 ms
29 dB/minimum
±10 dB
DTMF transmit
Minimum tone duration
Transmit level
Twist range
16 tones (0~9,
*
, #, A~D)
50 ms
7 dBm nominal
2~3 dB
Progress Tones Standard and proprietary, in 350~640 Hz frequency
range
Frequency response 200~300 Hz ± 3 dB/minimum
Speech Parameters 13 dB/minimum average transmit level for a 32
dBm receive level
Voice Coding Scheme 64 Kbs u-Law PCM, 32 Kbs ADPCM compression