Toshiba X500 Personal Computer User Manual


 
Replacement Procedures
4.20 LCD unit / FL inverter
CAUTION: When replacing a LCD, it is required that SVP parameter is set. Update with
the latest EC/KBC as described in Appendix H “EC/KBC Rewrite
Procedures”.
Removing the LCD unit / FL inverter
The following describes the procedure for removing the LCD unit and FL inverter (See
Figure 4-20-1 to 4-20-4).
Remove Screw MYLAR cover X8
1. Remove the following screws securing the display mask
M2.56.5 screw X8
2. Insert your finger between the edge of the display mask and the LCD, and remove the
display mask while releasing the latches of display mask.
Figure 4-20-1 Remove the display mask
Qosmio X500 Maintenance Manual (960-Q08)
5