TP-Link TL-SG3424P Switch User Manual


 
192
Rx_Only) to Tx&Rx (or Tx_Only), the fast start mechanism will be enabled, that
is, the transmit interval will be shorten to a second, and several LLDPDUs will
be sent out (the number of LLDPDUs equals this parameter). The default value
is 3.
Command Mode
Global Configuration Mode
Example
Specify the Transmit Interval of LLDPDU as 45 seconds and Trap message to
NMS as 120 seconds:
TP-LINK(config)# lldp timer tx-interval 45
TP-LINK(config)# lldp timer notify-interval 120
lldp med-fast-count
Description
The lldp med-fast-count command is used to configure the number of the
LLDP-MED frames that will be sent out. When LLDP-MED fast start mechanism
is activated, multiple LLDP-MED frames will be transmitted based on this
parameter. The default value is 4. To return to the default configuration, please
use no lldp med-fast-count command.
Syntax
lldp med-fast-count count
no lldp med-fast-count
Parameter
count —— Configure the Fast Start Count parameter. It ranges from 1 to 10. By
default, it is 4.
Command Mode
Global Configuration Mode
Example
Specify Fast Start Count as 5:
TP-LINK(config)# lldp med-fast-count 5
lldp admin-status
Description