Vidikron 30ET Projector User Manual


 
Vidikron Vision 30 Series Owner’s Operating Manual 53
PRE
L
IMINAR
Y
5.1
Lamp Replacement
The lamp should be replaced when it reaches the end of its life (typically 2000 hours), or
sooner if a noticeable degradation in brightness occurs. Contact your Vidikron dealer to
obtain a replacement lamp.
1. Turn off the projector and unplug the power cord.
Allow the projector to cool down for
approximately 45 minutes prior to removing the
lamp assembly for replacement.
2. Remove the two screws from the lamp cover.
3. Remove the lamp cover.
4. Remove the two lamp assembly mounting screws.
5. Grasp the lamp assembly handle and pull gently,
removing the lamp module from the projector
housing.
6. Install the new lamp module and replace the two
screws you removed in Step 4.
7. Replace the lamp cover at the top first and secure it
with the two screws you removed in
Step 2.
8. Turn on the power and select Lamp Reset Timer from
the Service menu to reset the lamp timer (refer to
Lamp Reset Timer on page 48).
5Maintenance and Troubleshooting