Vixel 335 Switch User Manual


 
Vixel Model 335 Installation & Configuration Guide CHAPTER 3 Management
22
RRDY The receiving node on this port has sent an R_RDY signal,
indicating that it is ready for a frame to be transmitted over the
link.
CLS The port is attempting to begin the process of closing the current
loop circuit.
OPN The port is attempting to open communications with another
port on the loop. Note: As is the case with some ordered sets, an
OPN may not go all the way around the loop, instead stopping
at its destination.
LIP F8 A non-switching port has detected a loop failure on its receive
input, is notifying other ports, and is determining whether the
loop is still operational.
Some events that could cause the port to detect loop failure
follow:
A device in the loop has failed.
A device in the loop has been powered off.
The physical connection between the transmitter and receiver
is broken.
Activating the port bypass circuit does not typically result in a
loop failure.
LIP F7 A loop port is in the non-participating mode and is attempting
to win arbitration and begin initialization, possibly because the
port was reset or is powering up. Sometimes the port is sending
this sequence to another, hot-cascaded switch like a new initiator
being inserted in the loop.
LIP A Loop Initialization Primitive (LIP) sequence has been detected
and action has been taken.
Unknown The switch can not determine what is being transmitted.
InvTxWd An invalid transmit word has been detected.
CRC Err A Frame CRC error has been detected.
Pt-to-Pt A point-to-point connection has been detected.