Xantrex Technology 175 PLUS Power Supply User Manual


 
40
The AC product(s) connected are
rated at less than the inverter’s
continuous power rating; high
starting surge has caused
overload shutdown.
The product exceeds the inverter’s
surge capability. Use a product with
a starting surge power within the
XPower’s capability.
Battery is discharged (alarm is
sounding).
Recharge battery.
The inverter has overheated due
to poor ventilation and has
shutdown (alarm is sounding).
Switch inverter OFF and allow to
cool for 15 minutes. Clear blocked
fan or remove objects covering unit.
Move the inverter to a cooler place.
Reduce load if continuous operation
is required.
Input voltage is greater than 15
volts.
Verify the charging system is
properly regulated and the battery is
12 volts nominal.
Possible Cause Suggested Remedy