Xerox 83xx Printer User Manual


 
3-14
3.3.1.2 Adjusting the tensioning systems
Introduction
The present topic describes the adjustment of the REAR tensioning system. The procedure to adjust the
front tensioning system is the same.
Procedure
Step 1 : Standing at the REAR SIDE of the unit, remove the cover (1) of the adjustable bracket (3).
Tool : Hexagon wrench 2,5 mm
No Description
1 Cover
2 Screws
3 Adjustable bracket
Step 2 : Loosen (don’t remove) the 4 screws on the side of the adjustable bracket.
Tool : Hexagon wrench 4 mm
No Description
1 Screws
2 Adjustable bracket