Xerox 8850 Copier User Manual


 
XEROX WIDE FORMAT COPY SYSTEM Main Menu 127
The second and third lines contain the log entry information in columnar
format. The first column indicates the log entry number. The second
column indicates the fault code recorded in the log. The third column is
the value of the internal Scanner Usage Meter at the time the fault was
detected.
Below is an example of the SCANNER FAULTS (ORDERED) screen.
SCANNER FAULTS (ORDERED)
LAST CLEARED: 2001
01 01-02
2476
02 01-03
2402
Scanner Faults (Ordered) Screen
8. Use the
Previous or Next key to scroll through the listing.
The entries are presented three to a screen. You can view all valid
entries in the Scanner Fault Log from this screen. Empty log entries are
not displayed.
9. When finished viewing the fault data, press the
Exit key to return
to the SCANNER DIAGNOSTICS menu screen.
Select the SCANNER FAULTS (COUNT) option to view the last cleared
faults.
To run the SCANNER FAULTS (COUNTS) diagnostic:
1. Press the
Menu key. The MAIN MENU screen is displayed.
2. Press the
Next key until DIAGNOSTICS is highlighted.
3. Press the
Enter key to select DIAGNOSTICS. The
DIAGNOSTICS menu screen is displayed.
4. Press the
Next key until SCANNER DIAGNOSTICS is displayed.
5. Press the
Enter key to select SCANNER DIAGNOSTICS. The
SCANNER DIAGNOSTICS menu screen is displayed.
6. Press the
Next key until SCANNER FAULTS (COUNTS) is
highlighted.
7. Press the
Enter key to select SCANNER FAULTS (COUNTS).
The SCANNER FAULTS (COUNTS) screen is displayed.
The first line of the display contains the value of the internal Scanner
Reliability Meter reading when the log was last cleared. If the log has
never been cleared, the value is set to zero. This line scrolls with the log
data.
The second and third lines contain the log entry information in columnar
format. The first column indicates the log entry number. The second
column indicates the fault code recorded in the log. The third column is
the value of the internal Scanner Usage Meter at the time the fault was
detected.
Below is an example of the SCANNER FAULTS (COUNTS) screen.
SCANNER FAULTS
(COUNT)