Using AutoSense The AutoSense feature sets sensitivity of the
transmissive sensor and measures and stores
the form (label) and gap lengths. To activate the
AutoSense feature:
Step 1 Set the power switch to the OFF (0) position.
Step 2 Load labels into the printer (do not use the dis
-
penser).
Step 3 Press and hold the FEED Control button while
placing the power switch in the ON (1) position.
The STATUS Indicator light will blink. Release
the FEED Control when the printer starts feed-
ing labels and the indicator turns solid green. Do
not hold the FEED Control button more than 5
seconds.
The printer will advance 3-4 labels while per-
forming the adjustment. When the adjustment
is complete, a status summary label will be
printed and the printer will be placed in Diag-
nostic Dump mode.
Dump Mode
Sample Printout
980181-001 Rev.C 33