3Com 3C16710 Switch User Manual


 
Setting Up the Alert LED
4-17
Coax Port Partition
Enabled /
Disabled
Allows you to specify whether the Alert LED lights if
the coaxial port becomes partitioned.
If this condition is resolved after causing the Alert
LED to light, the LED goes off (it stays lit if other
conditions also caused it to light).
Login Violation
Enabled /
Disabled
Allows you to specify whether the Alert LED lights if
a login violation occurs, which happens if a user
attempts to log on to your hub using the VT100
screens with an invalid username/password
combination three consecutive times.
If this condition caused the Alert LED to light, the
LED goes off after you have acknowledged the alert
by pressing the associated
Ack
button (the LED stays
lit if other conditions also caused it to light).
Port Security Violation
Enabled /
Disabled
Allows you to specify whether the Alert LED lights if
a port security violation occurs, which happens if an
unauthorized device attempts to communicate
through your hub.
If this condition caused the Alert LED to light, the
LED goes off after you have acknowledged the alert
by pressing the associated
Ack
button (the LED stays
lit if other conditions also caused it to light).
Authentication Failure
Enabled /
Disabled
Allows you to specify whether the Alert LED lights if
an authentication failure occurs, which happens if a
user attempts to access information on your hub
using an invalid community string.
If this condition caused the Alert LED to light, the
LED goes off after you have acknowledged the alert
by pressing the associated
Ack
button (the LED stays
lit if other conditions also caused it to light).
WorkGroup Monitor Failure
Enabled /
Disabled
Allows you to specify whether the Alert LED lights if
a
workgroup monitor f
ailure occurs, which happens if
a remote device fails to respond to a
workgroup
monitor p
oll from your hub.
If this condition caused the Alert LED to light, the
LED goes off after you have acknowledged the alert
by pressing the associated
Ack
button (the LED stays
lit if other conditions also caused it to light).
16710.bk : MANAGING.FRM Page 17 Tuesday, October 7, 1997 11:38 AM