Actiontec electronic V.90 Fax Machine User Manual


 
29
Range: 0-127
Default: 8
S6 Wait Before Blind Dialing
The value of S6 specifies the amount of time that must elapse after the modem
goes off-hook before the modem starts dialing the telephone number. The modem
waits for at least 2 seconds before dialing even if the register is set for a value less
than two.
Range: 2-255
Default: 2
S7 Wait for Carrier/Dial Tone
S7 specifies the length of time the modem waits to detect the remote modem car-
rier after dialing. If the remote modem is not detected within that time, the modem
hangs up and sends the NO CARRIER response.
Range: 1-255 seconds
Default: 60 seconds
S10 Lost Carrier Hang Up Delay
S10 is used to specify the length of time the modem waits before hanging up if the
remote modem carrier signal is lost. When set to 255, the modem does not hang
up when it loses the remote modem.
Range: 1-255 (1/10 of a second)
Default: 14 (1.4 seconds)
S11 DTMF Dialing Speed
S11 specifies the duration of DTMF (tone) dialing. This register is not used for
pulse dialing.
Range: 50-255 ms.
Default: 70 ms.
S12 Guard Time
S12 is used to specify guard and detect times used for the escape sequence.
Range: 1-255 (1/50 of a second)