Adaptec ANA-5930 Network Card User Manual


 
B-8
ANA-5910/5930/5940 User’s Guide
W0132 ATMO_ALP:
nic_proc_xmt_complete() room too
large, room variable
The available room in the transmit
queue on the adapter has become
larger than the configured value.
Reboot the computer. If you see this
message again, call technical support.
W0133 ATMO_ALP:
nic_proc_xmt_complete() logic error:
The driver received an interrupt that
indicated that a PDU had just been
transmitted. However nothing is in
the PDU queue to be transmitted.
Reboot the computer. If you see this
message again, call technical support.
W0135 ATMO_ALP: BAD RCV
reinitialize
W0137 ATMO_ALP: nic_service_vcc:
rcv BAD: variable
W0138 ATMO_ALP: rsi_descstart BD:
variable rcv_descstart variable
The adapter is being reset because of
some hardware errors. No action is
required; the computer will recover by
itself. A lost packet may be observed
by the applications.
W0139 ATMO_ALP: WRONG RCV
buffer size: variable
Because of an error in the software/
hardware, the calculated size of an
incoming PDU is larger than the
adapter’s receive segment size. The
adapter will reset and the computer
should recover by itself.
W0140 ATMO_ALP:
nic_rcv_seg_copyin: BAD count:
variable
There is an inconsistency in the
number of bytes being slave copied.
No action is required. However, if you
repeatedly see this message, call
technical support.
W0142 ATMO_ALP: nic_proc_error()
enter
The adapter is resetting because of
some hardware errors. No action is
required on the part of the
administrator or users. The computer
will recover by itself. A lost packet
may be observed by the applications.
Driver Console Error Message Description