ADC P-90-250 Network Card User Manual


 
ADCP-90-250
Issue 1, November 1996
Page 9
1996, ADC Telecommunications, Inc.
8519-A
CABLE CLAMP
MOUNTING PLATE
RUBBER
GROMMET
#4 MOUNTING
SCREWS
CABLE
CLAMP
YOKES
CABLE CLAMP
TOP PLATE
CLAMP
SCREWS
Figure 7. Lower Cable Clamp Assembly Details
8520-A
CABLE CLAMP
MOUNTING PLATE
RUBBER
GROMMET
#4 MOUNTING
SCREWS
CABLE
CLAMP
YOKES
CABLE CLAMP
TOP PLATE
CLAMP
SCREWS
Figure 8. Upper Cable Clamp Assembly Details
Splicing OSP Cable(s) to Fiber Cables
2.08
If the soft wall bundle fiber cables are already installed and routed to the splice trays,
prepare the ends of the OSP cable(s) and splice them to the fiber cables according to local
practice for heat shrink fusion splices. For your convenience, Figure 9 provides a cross reference
between the retainer/adapter positions and the color-coded fibers in the fiber cables. The adapter
numbers are also marked approximately two inches (five cm) from the end of the cable jacket at
the stub ends of the fibers.