PROVISIONING TASKS
After H2TU-C-231 is successfully installed, perform these basic provisioning tasks.
Setdateandtime(seeSetting Date and Timebelow)
Set circuit ID numbers (see Setting Circuit ID Numberson page 14)
Make any necessary configuration changes (see Configuring the Systemon page 15)
Clear history, alarm, and event log screens to remove miscellaneous data during startup (see Clearing the
History, Alarm, and Event Log Screenson page 23)
Setting Date and Time
Figure 4. Config Menu - Date and Time
1 Press to select the Config menu.
2 Use the and arrow keys to select Date and Time,thenpress .
3 Type the date in the format indicated, then press .
Rlogon/Rlogout Remote logon can be performed from the H2TU-C or H2TU-R. The screen displays “Rlogout”
when the H2TU-C or H2TU-R is remotely logged on to the other unit at the end of the circuit.
Remote logon from the H2TU-C will permit viewing of the H2TU-R and BERT Signal
Generator configuration submenu.
To log off from the remote unit, press . “Rlogout” changes to “Rlogon”. The unit is now
locally logged on until is pressed again to re-initiate the remote logon.
Help Provides a glossary of terms used in the maintenance screens, a list of navigational keys, and
ADC contact information.
Table 4. Logon Screen Menus (Continued)
Press this
key:
To access this
menu:
Menu Functions
R
R
R
H
Monitor Performance Event Log Config Inventory Report Rlogon Help
+----------------------+
|
Standard Options -> |
| ADC Options -> |
| BERT Generator -> |
|
Date and Time -> |
+-------------------------------+
| Date (mm/dd/yyyy):
05/15/2001|
| Time (hh:mm[:ss]): 12:30:01 |
+-------------------------------+
ID: xxxx--xxxx-xxxx--xxxx 09/01/2001 12:30:01 H2TU-C System: OK___