ADC H2TU-C-231 Network Card User Manual


 
LTPH-UM-1109-01, Issue 1 Testing
H2TU-C-231 List 2 January 9, 2002 49
A1LB, A2LB, and A5LB Test Procedures
Using the codes listed in Table 17, a network tester can activate NLOC or NREM loopbacks (or SMJK, if
enabled). A tester at the customer premises can activate CLOC, CRG, or CREM loopbacks. All loopbacks shown
in Table 17 can also be initiated from the H2TU-C-231 front-panel MODE and SEL pushbuttons (see Setting
Options through MODE and SELon page 9).
Table 17. Addressable Repeater Loopback Commands (A1LB, A2LB, A5LB)
Name Binary Code
(a)
(Hexadecimal Equivalent)
(a) The leftmost bit arrives first in all sequences. The detection algorithm functions reliably with a random 10
-3
BER on the facility.
The entire arming and loopback sequence can also be initiated at the remote H2TU-R location.
Description
ARMING or NI LPBK (inband) 11000-11000 ... Arming code
ARMING or NI LPBK (ESF Data
Link)
1111-1111-0100-1000 (FF48) Arming code
LPDN or DISARM (inband) 11100-11100 ... Disarming code
IR LPDN or DISARM (ESF Data
Link)
1111-1111-0010-0100 (FF24) Disarming code
IOR LPBK (NLOC or CREM)
230-232 bit errors
229-231 bit errors
(b)
(b) The H2TU-R identifies CREM (and the H2TU-C identifies NLOC) with 231 bit errors, including the frame bits. When framed
data is being sent in the Auto framing mode, the number of the 231 bit errors detected by the test set varies from 229 to 231,
depending on whether or not the test set counts frame errors as bit errors and on the number of frame bits contained in the
block of 231 error bits. The H2TU-R and H2TU-C generate this bit pattern in a series of discontinuous bursts containing 20-bit
errors each, including frame bits. Those test sets that do not count frame error bits as data bit errors will indicate fewer bits
than the H2TU-R and H2TU-C transmit for a CI and NI loopback.
1101-0011-1101-0011 (D3D3) NLOCDSX-1 signal is looped back to the network
at the H2TU-C-231.
CREMDS1 signal from customer is looped back to
the customer at the H2TU-C-231.
ILR-2 LPBK (NREM or CLOC)
20 bit errors
(c)
(c) The H2TU-R is assigned the ILR-2 loopback code. It responds with 20 bit errors (excluding the frame bits).
1100-0111-0100-0010 (C742) NREMDSX-1 signal is looped back to the network
at the H2TU-R.
CLOCDS1 signal from customer is looped back to
the customer at the H2TU-R.
IR LPDN 1001-0011-1001-0011 (9393) Loopdown (H2TU-C or H2TU-R)
IR QUERY LPBK 1101-0101-1101-0101 (D5D5) Query loopback
IR ALTERNATE QUERY LPBK 1101-0101-1110-1010 (D5EA) Alternate query loopback
TIME-OUT OVERRIDE 1101-0101-1101-0110 (D5D6) Loopback time-out override
Far End NI ACTIVATE
(d)
(d) Sending the Far End NI Activate code is not required in A5LB because it is always activated.
1100-0101-0101-0100 (C554) Unblock AIS
IOR POWER DOWN (H2TU-C)
(e)
(e) The IOR Power Down code must remain present for the duration of the powerdown mode. When this code is removed, the
HiGain HDSL2 system returns to its normal unlooped and unarmed state.
0110-0111-0110-0111 (6767) Removes HDSL2 line power