Manual Loopback Session
A manual loopback session allows you to select any one of the HiGain HDSL2 loopbacks listed in Table 16 on
page 44 with the exception of SmartJack loopbacks, which can only be issued by inband commands.
Setting the Loopback Time-Out Option
Before initiating a loopback session, verify that the Loopback Time-Out parameter is set to the desired setting.
1 Use the MODE and SEL pushbuttons as described in Setting Options through MODE and SELon page 9.
(The Loopback Time-Out parameter is also user-selectable from the System Settings screen when using a
maintenance terminal.)
2 Select the desired setting:
NONE (time-out disabled)
20 minutes
60 minutes (default setting)
120 minutes
8 hours
24 hours
Activating Manual Loopback Mode
To initiate a manual loopback session:
1 Press both the MODE and SEL pushbuttons on the front panel for at least 5 seconds. The following message
appears on the front-panel display:
MAN LPBK NLO?
2 Press SEL to activate NLOC. The display changes to MAN LPBK NLOC.
3 Press MODE to advance to the next available loopback:
NRE? = NREM
CRE? = CREM
CLO? = CLOC
With the exception of SmartJack, any of the HiGain HDSL2 loopbacks can be executed using the
MODE and SEL pushbuttons.
When executing a manual loopback session using the MODE and SEL pushbuttons:
The next loopback option can be displayed by pressing the MODE pushbutton, however, the
previously activated loopback remains active until the SEL pushbutton is pressed, which
activates the new loopback.
If neither pushbutton is pressed for a period of 30 seconds and no loopback is in effect, the
manual loopback session terminates, and the display returns to normal mode.
If any loopback is in effect, the 30-second time-out is inhibited. The active loopback and the
manual loopback sessions continue until the loopback times out in accordance with the
LBTO setting.
If there is an active loopback, pressing the MODE and SEL pushbuttons for 3 or more
seconds terminates any active loopback, ends the manual loopback session, and returns the
display to normal mode.