ADC HDSL4 Network Card User Manual


 
Installation LTPH-UM-1031-03, Issue 3
8 September 12, 2003 H4TU-C-319 List 1
INSTALLATION
Figure 2. Installing the H4TU-C-319 List 1 into a Shelf
1 Align the H4TU-C with the enclosure slot guides, then push the unit in until it touches the backplane
card-edge connector.
2 Place your thumbs on the front panel and push the H4TU-C into the slot guides until properly seated.
Upon receipt of the equipment, inspect the contents for signs of damage. If the equipment has
been damaged in transit, immediately report the extent of damage to the transportation
company and to ADC.
When installing an H4TU-C in a chassis, be sure to wear an antistatic wrist strap. Avoid touching
components on the circuit board.
To comply with the intrabuilding wiring requirements of GR-1089 CORE, Section 4.5.9, the
shields of the ABAM-type cables that connect the H4TU-C DSX-1 output ports to the
cross-connect panel must be grounded at both ends.
H4TU-C-319
CO shelf