ADC HDSL4 Network Card User Manual


 
LTPH-UM-1031-03, Issue 3 Monitoring System Activity and Performance
H4TU-C-319 List 1 September 12, 2003 35
USING THE PERFORMANCE SCREENS TO VIEW ALARM DATA
To access the alarm history screens:
1 Press to select the Performance screen.
2 Press the to select an interface (H4TU-C DS1, H4TU-R DS1, H4TU-C HDSL, H4DU-1 NET
HDSL, H4DU-1 CPE HDSL, H4DU-2 NET HDSL, H4DU-2 CPE HDSL, or H4TU-R HDSL), then press
.
3 Press the until Alarm History is selected, then press . (To clear the selected alarm history
screen, press .)
Alarm History at the DS1 Interface
The Alarm History screen reports DS1 statistics for the H4TU-C (Figure 22) and the H4TU-R (Figure 23 on
page 36) on a continuous basis. The types of alarms reported are described in Table 11 on page 36. Current alarms
are shown in reverse video.
Figure 22. H4TU-C DS1 Alarm History Screen
P
SPACEBAR
ENTER
SPACEBAR ENTER
L
M
onitor Performance Event Log Config Inventory Report Rlogon Help
H4TU-C DS1 Alarm History
-----------------------------------------------------------------------------
Alarm First Last Status Count
LLOS 01/30/02 ALARM 12
LAIS OK 0
DBER OK 7
LOF 01/30/02 OK 0
Press: C(l)ear Alarm History
-----------------------------------------------------------------------------
Use <Space> to cycle through Interface : H4TU-C DS1
choices and <Enter> to view Statistics : Alarm History
ID: xxxx--xxxx--xxxx—-xxxx 02/01/2002 12:30:01 H4TU-C System: Alarm