Configuration switch settings
The underside of the TS4 unit features a block of eight switches which are used
to configure various fundamental settings. When shipped, all switches are set to
OFF, which produces normal operation within the TS4 unit. Further details about
switch settings can be found within sections of this guide dealing with specific
setup issues.
8
OFF: Normal operation
ON: (while power applied) Reset unit
6
OFF: Cycle between all system ports
ON: Cycle between active ports only
7
OFF: Normal operation
ON: Upgrade mode
5
OFF: Normal operation
ON: Synchrony mode
1
OFF: Normal operation
ON: Auto switch to powered port
2,3,4
Reserved
Note: The switch settings (except switch 8) are
consulted by the unit only during its power up
phase, i.e. when power is first supplied by a
keyboard socket of a powered system. Therefore,
change the setting while the unit is disconnected
or use switch 8 to force a reset, whereupon the
other switches will be consulted.