ADTRAN TSU 120 Network Card User Manual


 
Chapter 3. Operation
3-12
TSU 120 User Manual 61202129L1-1
To use SNMP via SLIP port, follow these steps:
Terminal Mode
The TSU 120 provides the front panel menus to a VT 100-type
terminal. This mode can be used to configure and monitor the
unit. Initiate this mode by keying in
<CTRL> PTT
on the termi-
nal once it is connected to the chain-in port. For more informa-
tion on this method of control, see Chapter 8, Telnet/Terminal
Menus on page 8-1.
TELNET
To connect to the TSU 120 via TELNET, follow these steps.
Only one TELNET session can be active at one time.
Step Action
1 Set
C
ONTROL
P
ORT
to
SLIP
.
2 Set the
IP
ADDRESS
. The
DEFAULT
GATEWAY
, and
SUBNET
MASK
are not used in SLIP.
3 The appropriate MIB browser must be loaded into the
Network Management Station (available on the
ADTRAN webpage at http://www.adtran.com).
4 The MIB browser issues SNMP gets/sets to the TSU
120e.
Step Action
1 Before attempting to connect via TELNET, first define
the IP address, the default gateway, and the subnet
mask using the front panel.
2 When you begin the TELNET session, you will be
prompted for a password. The default password is
ADTRAN
.
3 You can change this password using the Management
submenu. See Default Unit Passcode on page 8-7 for
more information.
4 The TELNET session will time out after a predefined
value that is also set in the Management menu.