ADTRAN TA 544 Network Card User Manual


 
TA 544 User Manual/61200704L1-1A
Page 23 of 68
© 2001, ADTRAN, Inc. TA 544 User Manual
Start Transfer
This activator is used when the configurable items in this menu are complete.
Abort Transfer
Use this activator to cancel any TFTP transfer in progress.
TFTP Server
Setting this to Y
ES
allows another TA 544 to upgrade its code using TFTP client. This, in effect, turns on the
TA 544 TFTP server function and allows its code to be “cloned.” Setting to N
O
(def) will deny any request
from TFTP clients.
> Config Transfer
Sends a file containing the TA 544 configuration to a PC connected to the CRAFT port using XMODEM protocol or
to a file on a TFTP server using the TFTP protocol. See Appendix B. Updating TA 544 Firmware using XMODEM
on page 51 and Appendix C. Updating TA 544 Firmware using TFTP on page 54 for details.
C
ONFIG
T
RANSFER
also lets you save the TA 544 configuration as a backup file, so you can use the same configuration
with multiple TA 544 units. In addition, C
ONFIG
T
RANSFER
can retrieve a configuration file from a TFTP server.
To support these transfers, ADTRAN delivers a TFTP program with the TA 544 called TFTP Server. You can con-
figure any PC running Microsoft Windows with this software, and store a configuration file.
Only one configuration transfer session (upload or download) can be active at a time.
Transfer Method
Displays the method used to transfer the configuration file to or from a server. XMODEM and TFTP are
supported.
Transfer Type
Only B
INARY
transfers are currently supported.
TFTP Server IP Address
Specifies the IP address of the TFTP server. Get this number from your system administrator.
Before using S
TART
T
RANSFER
, the TA 544 should have a valid IP address, subnet mask, and
default gateway (if required).
Before using C
ONFIG
T
RANSFER
, the TA 544 should have a valid IP address, subnet mask, and
default gateway (if required).